DC Two output 5V12V 80W Switching Power Supply

Huyssen’s multiple output power supplies are range from 40 Watts to 600 Watts, output voltage from 5 VDC to 48VDC or higher. Dual output, triple output, and quad output are available, accept customize. Many electronics applications & equipment require multiple voltages to supply their various internal circuits. It can save time, space, and money in some applications, please contact us for more.

Products Details

MODEL

HSJ-80-2412

HSJ-80-0512

HSJ-80-1212

OUTPUT OUTPUT NUMBER

CH1

CH2

CH1

CH2

CH1

CH2

DC VOLTAGE

12V

24V

5V

12V

-12V

12V

RATED CURRENT

2.6A

2A

4A

5A

2A

5.6A

RATED POWER

       80W

        80W

        80W

RIPPLE&NOISE

120mVp-p

240mVp-p

80mVp-p

120mVp-p

120mVp-p

120mVp-p

VOLTAGEADJ.RANGE

CH1: 4.75~5.5V

CH1: 4.75~5.5V

CH1: 11.5 ~ 15.5V

VOLTAGETOLERANCE

±2.0%

±6.0%

±2.0%

±5.0%

±4.0%

±4.0%

LINEREGULATION

±0.5%

±1.5%

±0.5%

±1.0%

±0.5%

±0.5%

LOADREGULATION

±0.5%

±3.0%

±0.5%

±2.0%

±3.0%

±3.0%

SETUP.RISEHOLD.TIME 500ms, 30ms/230VAC          1200ms, 30ms/115VAC at full load
HOLD TIME 80ms/230VAC          16ms/115VAC at full load
INPUT VOLTAGE RANGE 88 ~ 264VAC  125 ~ 373VDC (Withstand 300VAC surge for 5sec. Without damage)
FREQUENCYRANGE 47~63HZ
EFFICIENCY

84%

78%

82%

AC CURRENT 0.8A/115VAC           0.55A/230VAC
INRUSH CURRENT COLD START 36A/230VAC
LEAKAGECURRENT <2mA/240VAC
PROTECTION OVERLOAD 110~150% rated output power
Protection type: Hiccup mode,recovers automatically after fault condition is removed
OVER VOLTAGE  YES  YES
Protection type : Hiccup mode, recovers automatically after fault condition is removed
ENVIRONMENT WORKING TIMP -25~+70°C (Refer to "Derating Curve")
WORKINGHUMIDITY 20~90% RH non-condensing
STORAGE TEMP HUMIDITY -40~+85°C   10~95%RH
TEMPCOEFFICIENT ±0.03%/ °C(0~50°C) on CH1 output
VIBRATION 10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY&EMC SAFETYSTANDARDS U60950, TUV EN60950 approved
WITHSTAND VOLTAGE I/P-O/P:3KVAC     I/P-FG:2KVAC     O/P-FG:0.5KVAC
ISOLATIONRESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25°C/ 70% RH
EMC EMISSION Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3
EMC IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11, EN61000-6-2 (EN50082-2), heavy industry level, criteria A
QTHERS MTBF 179Khrs min.      MIL-HDBK-217F (25°C )
DIMENSION 88*70*38mm (L*W*H)
PACKING 0.4Kg; 30PCS/9Kg
 Industrial control equipment, self-service terminal equipment, medical equipment, communication equipment, animation products, game consoles, beauty equipment, etc.Huyssen dual Output Power Supply Universal AC input : 90-264V Protections: Short circuit / Overload / Over voltage / over current Cooling by free air convection High efficiency, long life and high reliability All using 105°C long life electrolytic capacitors High operating temperature up to 70°C LED indicator for power on 100% full load burn-in test 24 months warranty

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours