AC/DC 12V 12.5A 150W Thin Switching Power supply LRS-150-12

Huyssen Power's Switching power supplies Input Voltages is from 90-264VAC, 50-60Hz, with some models offering an optional industrial grade 277VAC, output power range from 5W to 2,000W. Output Voltages offered between 3 to 500VDC or more.  In addition to our wide range of standard products, we also provide customized power supply services, please contact us directly!

Products Details

Features: Huyssen Power Supply 12V12.5A AC input 110/220VAC Low leakage current <2mA   Protections: Short circuit / Overload / Over voltage / Over temperature Cooling by air Withstand 300vac surge input for 5 second Conformal coated LED indicator for power on Low cost, high reliability 100% full load burn-in test 2 years warranty Specifications:

Model

LRS-150-5

LRS-150-12

LRS-150-15

LRS-150-24

LRS-150-36

LRS-150-48

      output DC voltage

5V

12V

15V

24V

36V

48V

Rated current

20A

12.5A

10A

6.5A

4.3A

3.3A

Current range

0~20A

0~12.5A

0~10A

0~6.5A

0~4.3A

0~3.3A

Rated power

120W

150W

150W

156W

154.8W

158.4W

Ripple&noise

120mVp-p

150mVp-p

150mVp-p

200mVp-p

200mVp-p

200mVp-p

DC voltage ADJ. range

±10%

±10%

±10%

±10%

±10%

±10%

Voltage tolerance Note.3

±3%

±2%

±1%

±1%

±1%

±1%

Line regulation Note.4

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

Load regulation Note.5

±2%

±1%

±0.5%

±0.5%

±0.5%

±0.5%

Setup,rise,hold up time 800ms,30ms,40ms/230VAC(full load)
    input Voltage range 90~132VAC/170~264VAC(selected by switch),240~373VDC
Frequency range 47~63HZ
AC current 2.8A/115VAC     1.6A/230VAC
Inrush current Cold start 50A/230VAC
Efficiency

80%

83%

85%

86%

88% 90%
Leakage current <0.75mA/240VAC
  protection overload Rated output power110%~150%  start over load protection
protection type:hiccup mode,auto-recovery after fault condition is removed
Over voltage Rated output voltage 115%~135% Start over voltage protection
Protection type:hiccup mode,auto-recovery after fault condition is removed
Over temperature 100℃±10℃(RT1 detect beside transformer)      
Protection type:cut off the output,auto-recovery after the temperature become normal
environment Working temp,humidity -30℃~+70℃(Please refer to“derating curve”) 20%~90%RH Non-condensing
Storage temp,humidity -40℃~+85℃,10%~95%RH non-condensing
Withstand vibration 10~500HZ,2G 10min/1cycle,period for 60 minutes,each axes
safety Withstand voltage I/P-O/P:3.75KVAC   I/P-FG:2KVAC   O/P-FG:1.25KVAC
Isolation resistance I/P-O/P,I/P-FG,O/P-FG:100M ohms/500VDC
Fit standard Safety standards Compliance to UL60950-1,TUV EN60950-1,GB4943
EMC emission Compliance to EN55022(CISPR22)Class A,GB9254 Class B,EN55014,EN61000-3-2,3
EMC immunity Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024,EN61000-6-1
others Dimension 159*97*30mm(L*W*H) 
Weight/packing 0.43kg/30pcs/13.9kg/0.023m³/0.82CUFT
MTBF ≥580K hrs min. MIL-HDBK-217F(25℃)
note 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4.Line regulation is measured from low line to high line at rated load. 5.Load regulation is measured from 0% to 100% rated load 6.The ambient temperature derating of 5℃/1000 m is needed for operating altitude greater than 2000m(6500ft) 7.The power supply is considered as a component which will be installed into a finalequipment.The final equipment must be re-confirmed that it still meets EMC directives.For guidance on how to perform these EMC tests.
    Related products: ASDHAJ Applications: Widely used in : Billboards, LED Lighting ,Display screen, 3D Printer, CCTV camera, Laptop, Audio ,Telecommunication ,STB , Intelligent robot, Industrial control, equipment, etc.

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours