100W 12V24V dual output Switching Power Supply

Huyssen’s multiple output power supplies are range from 40 Watts to 600 Watts, output voltage from 5 VDC to 48VDC or higher. Dual output, triple output, and quad output are available, accept customize. Many electronics applications & equipment require multiple voltages to supply their various internal circuits. It can save time, space, and money in some applications, please contact us for more.

Products Details

MODEL

HSJ-100-2412

HSJ-100-0512

HSJ-100-3612

OUTPUT OUTPUT NUMBER

CH1

CH2

CH1

CH2

CH1

CH2

DC VOLTAGE

12V

24V

5V

12V

36V

12V

RATED CURRENT

4.3A

2A

3A

7A

2A

2.3A

RATED POWER

100W

100W

100W

RIPPLE&NOISE

120mVp-p

240mVp-p

80mVp-p

240mVp-p

300mVp-p

120mVp-p

VOLTAGEADJ.RANGE

CH1: 4.75~5.5V

CH1: 4.75~5.5V

CH1: 11.5 ~ 15.5V

VOLTAGETOLERANCE

±2.0%

±6.0%

±2.0%

±5.0%

±4.0%

±4.0%

LINEREGULATION

±0.5%

±1.5%

±0.5%

±1.0%

±0.5%

±0.5%

LOADREGULATION

±0.5%

±3.0%

±0.5%

±2.0%

±3.0%

±3.0%

SETUP.RISEHOLD.TIME 500ms, 30ms/230VAC          1200ms, 30ms/115VAC at full load
HOLD TIME 80ms/230VAC          16ms/115VAC at full load
INPUT VOLTAGE RANGE 88 ~ 264VAC  125 ~ 373VDC (Withstand 300VAC surge for 5sec. Without damage)
FREQUENCYRANGE 47~63HZ
EFFICIENCY

86%

82%

80%

AC CURRENT 0.8A/115VAC           0.55A/230VAC
INRUSH CURRENT COLD START 36A/230VAC
LEAKAGECURRENT <2mA/240VAC
PROTECTION OVERLOAD 110~150% rated output power
Protection type: Hiccup mode,recovers automatically after fault condition is removed
OVER VOLTAGE  YES  YES
Protection type : Hiccup mode, recovers automatically after fault condition is removed
ENVIRONMENT WORKING TIMP -25~+70°C (Refer to "Derating Curve")
WORKINGHUMIDITY 20~90% RH non-condensing
STORAGE TEMP HUMIDITY -40~+85°C   10~95%RH
TEMPCOEFFICIENT ±0.03%/ °C(0~50°C) on CH1 output
VIBRATION 10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY&EMC SAFETYSTANDARDS U60950, TUV EN60950 approved
WITHSTAND VOLTAGE I/P-O/P:3KVAC     I/P-FG:2KVAC     O/P-FG:0.5KVAC
ISOLATIONRESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25°C/ 70% RH
EMC EMISSION Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3
EMC IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11, EN61000-6-2 (EN50082-2), heavy industry level, criteria A
QTHERS MTBF 179Khrs min.      MIL-HDBK-217F (25°C )
DIMENSION 160*98*40mm (L*W*H)
PACKING 0.55Kg; 20PCS/9Kg
Industrial control equipment, self-service terminal equipment, medical equipment, communication equipment, animation products, game consoles, beauty equipment, etc.Huyssen dual Output Power Supply Universal AC input : 90-264V Protections: Short circuit / Overload / Over voltage / over current Cooling by free air convection High efficiency, long life and high reliability All using 105°C long life electrolytic capacitors High operating temperature up to 70°C LED indicator for power on 100% full load burn-in test 24 months warranty

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours