| Technical Data | 1KW | 2KW | 3KW | 6KW | 8KW |
| AC:Supply | |||||
| - Voltage | 1Φ220VAC±10% | 3Φ380VAC±10% | |||
| - Frequency | 50/60HZ | ||||
| DC:Voltage | |||||
| - Accuracy | <0.1% of rated value | ||||
| - Load regulation 0-100% | <0.05% of rated value | ||||
| - Line regulation ±10%△UAC | <0.05% of rated value | ||||
| - Regulation 10-100% load | <5ms | ||||
| - Slew rate 10-90% | <10ms | ||||
| - Voltage compensation | 5% rated voltage or 5V | ||||
| - Ripple | <0.1% of rated value | ||||
| DC:Current | |||||
| - Accuracy | <0.15% of rated value | ||||
| - Load regulation 1-100% | <0.15% of rated value | ||||
| - Line regulation ±10%△UAC | <0.05% of rated value | ||||
| -DC:Power | |||||
| - Accuracy | <0.3% of rated value | ||||
| Protection |
| ||||
| Overvoltage protection, overcurrent protection, overload protection, over temperature protection | |||||
| Insulation | |||||
| - AC input to enclosure | 1500VDC | ||||
| - AC input to DC output | 1500VDC | ||||
| - DC output to enclosure (PE)enclosure(PE) | 500VDC | ||||
| Other |
| ||||
| - Digital interfaces | CAN,RS485 or RS232 | ||||
| - Dry contact Wet contact | Dry contact Wet contact | ||||
| - Cooling | Air cooling | ||||
| - Operation temperature | -5℃-45℃ | ||||
| - Storage temperature | -20℃-60℃ | ||||
| - Humidity | <80%,No condensation | ||||
| - Dimensions(W H D) | 325*88*450mm | 425*88*450mm | 425*132*551.5mm | ||
| - Weight | 9KG | 14KG | 25KG | ||
Applications: Aerospace Test Photovoltaic, Energy storage system New energy automotive Data center Industrial motor Power semiconductor device Automatic test system (ATE) Lithium battery, fuel cell electronic Equipment aging Precision plating, sputtering, surface treatment